Full metadata record

DC Field Value Language
dc.contributor.authorMin, BR-
dc.contributor.authorKim, SJ-
dc.contributor.authorAhn, KH-
dc.contributor.authorMoon, MH-
dc.date.accessioned2024-01-21T11:01:44Z-
dc.date.available2024-01-21T11:01:44Z-
dc.date.created2021-09-04-
dc.date.issued2002-03-15-
dc.identifier.issn0021-9673-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/139687-
dc.description.abstractHollow fiber flow FFF (HF FIFFF) has recently shown its capability to separate and characterize the size of submicrometer particles and has demonstrated the potential to be developed into a disposable flow FFF channel. In this work, HF FIFFF was used for the hyperlayer separation of micron-sized particles and the separation capability was examined by using various hollow fiber membrane materials (Polysulfones, cPVC, and PAN). From the experiments, PAN (polyacrylonitriles) showed an outstanding performance in particle separation compared to the other membranes. By orienting the fiber module in an upright direction, the upstream flow migration reduced band broadening of eluted peaks. When the efficiency of the PAN hollow fiber system was tested by varying the ratio of outflow-rate to radial flow-rate, it was found that optimum separation in hyperlayer HF FIFFF can be obtained at the ratio of about 6-7. From the examination of retention at or around steric inversion diameter, it was observed that experiments showed a good agreement with predictions by semi-empirical calculation. In hyperlayer HF FIFFF the diameter based selectivity values were shown to be 1.2-1.7 depending on the type of membranes and the field strength (the radial flow-rate) conditions. (C) 2002 Published by Elsevier Science B.V.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectPARTICLE SEPARATION-
dc.subjectSIZE CHARACTERIZATION-
dc.titleHyperlayer separation in hollow fiber flow field-flow fractionation: effect of membrane materials on resolution and selectivity-
dc.typeArticle-
dc.identifier.doi10.1016/S0021-9673(02)00029-8-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJOURNAL OF CHROMATOGRAPHY A, v.950, no.1-2, pp.175 - 182-
dc.citation.titleJOURNAL OF CHROMATOGRAPHY A-
dc.citation.volume950-
dc.citation.number1-2-
dc.citation.startPage175-
dc.citation.endPage182-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000174786200018-
dc.identifier.scopusid2-s2.0-0037087042-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusPARTICLE SEPARATION-
dc.subject.keywordPlusSIZE CHARACTERIZATION-
dc.subject.keywordAuthorhyperlayer separation-
dc.subject.keywordAuthorhollow fiber flow field-flow fractionation-
dc.subject.keywordAuthorresolution-
dc.subject.keywordAuthorselectivity-
dc.subject.keywordAuthorfield-flow fractionation-
Appears in Collections:
KIST Article > 2002
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE