Investigation of particle generation in a hard disk drive during the start/stop period
- Authors
- Park, HS; Yoo, YC; Bae, GN; Hwang, JH
- Issue Date
- 1999-09
- Publisher
- Institute of Electrical and Electronics Engineers
- Citation
- IEEE Transactions on Magnetics, v.35, no.5, pp.2439 - 2441
- Abstract
- Particle contamination in a hard disk drive has been recognized as an important issue because particles can significantly affect the reliability of the drive. In this study, characteristics of the particle generation in a hard disk drive during the start/stop period were investigated. The number of particles generated in the drive was measured at 5 locations using CNC (condensation nucleus counter) with a sampling probe. It was found that most of particles were generated whenever the drive started or stopped. The number of particles detected by the condensation nucleus counter depended on parameters including sampling location and sampling velocity.
- Keywords
- INTERFACE; particle
- ISSN
- 0018-9464
- URI
- https://pubs.kist.re.kr/handle/201004/141952
- DOI
- 10.1109/20.800851
- Appears in Collections:
- KIST Article > Others
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML