A novel convex acoustic lens-attached ultrasound drug delivery system and its testing in a murine melanoma subcutaneous model

Authors
박준홍Lee, SeunghyunJeon Ho yoonKim, Jung HoonKim, Da JungIm, MaesoonLee, Byung Chul
Issue Date
2023-07
Publisher
Elsevier BV
Citation
International Journal of Pharmaceutics, v.642
Abstract
Target-specific drug release is indispensable to improve chemotherapeutic efficacy as it enhances drug uptake and penetration into tumors. Sono-responsive drug-loaded nano-/micro-particles are a promising solution for achieving target specificity by exposing them to ultrasound near tumors. However, the complicated synthetic processes and limited ultrasound (US) exposure conditions, such as limited control of ultrasound focal depth and acoustic power, prevent the practical application of this approach in clinical practice. Here, we propose a convex acoustic lens-attached US (CALUS) as a simple, economic, and efficient alternative of focused US for drug delivery system (DDS) application. The CALUS was characterized both numerically and experimentally using a hydrophone. In vitro, microbubbles (MBs) inside microfluidic channels were destroyed using the CALUS with various acoustic parameters (acoustic pressure [P], pulse repetition frequency [PRF], and duty cycle) and flow velocity. In vivo, tumor inhibition was evaluated using melanoma-bearing mice by characterizing tumor growth rate, animal weight, and intratumoral drug concentration with/without CALUS DDS. US beams were measured to be efficiently converged by CALUS, which was consistent with our simulation results. The acoustic parameters were optimized through the CALUS-induced MB destruction test (P = 2.34 MPa, PRF = 100 kHz, and duty cycle = 9%); this optimal parameter combination successfully induced MB destruction inside the microfluidic channel with an average flow velocity of up to 9.6 cm/s. The CALUS also enhanced the therapeutic effects of an antitumor drug (doxorubicin) in vivo in a murine melanoma model. The combination of the doxorubicin and the CALUS inhibited tumor growth by ∼ 55% more than doxorubicin alone, clearly indicating synergistic antitumor efficacy. Our tumor growth inhibition performance was better than other methods based on drug carriers, even without a time-consuming and complicated chemical synthesis process. This result suggests that our novel, simple, economic, and efficient target-specific DDS may offer a transition from preclinical research to clinical trials and a potential treatment approach for patient-centered healthcare.
Keywords
BLOOD-FLOW-VELOCITY; FOCUSED ULTRASOUND; MEDIATED DELIVERY; CANCER; BRAIN; PHASE; PERMEABILITY; EFFICACY; DESIGN; TUMORS; Acoustic lens; Ultrasound-mediated microbubble destruction; Drug delivery; Doxorubicin; Melanoma tumor; The authors would like to especially thank Yong Sub Shin (SNUH) for animal modeling and imaging scans
ISSN
0378-5173
URI
https://pubs.kist.re.kr/handle/201004/79884
DOI
10.1016/j.ijpharm.2023.123118
Appears in Collections:
KIST Article > 2023
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE