Oxygen-enriched air for co-incineration of organic sludges with municipal solid waste: A pilot plant experiment

Authors
Chin, SungminJurng, JongsooLee, Jae-HeonHur, Jin-Huek
Issue Date
2008-12
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Citation
WASTE MANAGEMENT, v.28, no.12, pp.2684 - 2689
Abstract
Pilot-plant experiments were performed to evaluate the effect of oxygen enrichment oil the co-incineration of MSW and organic sludge from a wastewater treatment facility. Combustion chamber temperatures, stack gas concentrations, i.e., CO2 and CO, and the residual oxygen were measured. The maximum ratio of organic sludge waste to total waste input was 30 wt.%. Oxygen-enriched air, 22 vol.% (dry basis) oxygen, was used for stable combustion. As the co-incineration ratio of the sludge increased, the primary and secondary combustion chamber temperatures were decreased to 900 and 750 degrees C, respectively, approximately 100 degrees C below the proper incineration. However, if the supplied air was enriched with 22 vol.% (dry basis) oxygen content, the incinerator temperature was high enough to burn the waste mixture containing 30 wt.% moisture sludge, with an estimated heating value of 6.72 MJ/kg. There are two main benefits of using oxygen enrichment in the co-incineration. First, the sensible heat can be reduced as the quantity of nitrogen in the flue gas will be decreased. Second, the unburned carbon formation is reduced due to the oxygen-enriched burning of the waste, despite an increase in the sludge co-incineration ratio. (C) 2008 Elsevier Ltd. All rights reserved.
Keywords
FLUIDIZED-BED; FLUIDIZED-BED; waste; oxygen-enriched; sludge; co-incineration; pilot plant
ISSN
0956-053X
URI
https://pubs.kist.re.kr/handle/201004/132940
DOI
10.1016/j.wasman.2008.01.004
Appears in Collections:
KIST Article > 2008
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE