Construction and measurements of HTS DC SQUID electronic gradiometer to be used in NDE systems

Authors
Kim, JKang, JLee, ESong, IHGohng, JHahn, TS
Issue Date
1999-06
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Citation
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, v.9, no.2, pp.4389 - 4392
Abstract
We have designed a non-destructive evaluation system by using an electronic gradiometer constructed with two DC SQUID magnetometers. Typical flux modulation of the SQUIDs used in this work was about 30 mu V and the noise at 10 Hz was about 14 mu Phi(0)/root Hz. The system includes a non-magnetic stainless steel dewar and a set of coaxial exciting coils, which was used to induce an eddy current in the test piece. The sample motion stage and the SQUIDs were computer controlled and the output data from the electronic gradiometer was obtained by using Labview software.
Keywords
electronic gradiometer
ISSN
1051-8223
URI
https://pubs.kist.re.kr/handle/201004/142157
DOI
10.1109/77.783997
Appears in Collections: