Full metadata record

DC Field Value Language
dc.contributor.authorPark, KD-
dc.contributor.authorSuzuki, K-
dc.contributor.authorLee, WK-
dc.contributor.authorLee, JE-
dc.contributor.authorKim, YH-
dc.contributor.authorSakurai, Y-
dc.contributor.authorOkano, T-
dc.date.accessioned2024-01-21T19:15:05Z-
dc.date.available2024-01-21T19:15:05Z-
dc.date.created2022-01-10-
dc.date.issued1996-09-
dc.identifier.issn1058-2916-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/144328-
dc.description.abstractPolyurethane (PU) surfaces were modified by coupling polyethylene glycol (PEG; molecular weight, 1,000) chains carrying different terminal groups (PU-PEC 1K-OH, PU-PEG1K-NH2, PU-PEG1K-SO3) and longer PEG chains (MW, 3,350; PU-PEG3.4K-OH). The modified PU surfaces have the same PEG (1K) chain density. Surface induced platelet activation was evaluated by measuring cytoplasmic free calcium concentration in platelets contacting modified surfaces, and platelet adhesion onto modified surfaces was investigated in vitro. Cytoplasmic free calcium levels in platelets contacting PU-PEG-SO3 remained relatively constant, in contrast to the significant increase observed for PU-PEC-NH2, PU-PEG-OH, and control PU surfaces. The degree of platelet adhesion clearly demonstrates that all PEG graft surfaces prevented platelet adhesion. Among PEG1K surfaces, PU-PEG-SO3 shows the lowest platelet adhesion. In the case of relatively longer PEG grafted surfaces (PU-PEG3.4K-OH and PU-PEG3.4K-Hep), both surfaces were found to prevent the increase in both cytoplasmic free calcium and platelet adhesion. These results suggest that longer PEG chain grafting is more effective than shorter grafting in preventing platelet activation and adhesion because of the highly dynamic movement of hydrated PEG chains at the interface. In addition, in vitro platelet interaction is dependent upon terminal groups of PEC chains on PEG1K series surfaces.-
dc.languageEnglish-
dc.publisherLIPPINCOTT-RAVEN PUBL-
dc.titlePlatelet adhesion and activation on polyethylene glycol modified polyurethane surfaces - Measurement of cytoplasmic calcium-
dc.typeArticle-
dc.identifier.doi10.1097/00002480-199609000-00117-
dc.description.journalClass1-
dc.identifier.bibliographicCitationASAIO JOURNAL, v.42, no.5, pp.M876 - M881-
dc.citation.titleASAIO JOURNAL-
dc.citation.volume42-
dc.citation.number5-
dc.citation.startPageM876-
dc.citation.endPageM881-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosidA1996VP50800116-
dc.identifier.scopusid2-s2.0-0346290930-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryTransplantation-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTransplantation-
dc.type.docTypeArticle-
Appears in Collections:
KIST Article > Others
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE