Practical contaminant analysis of lubricating oil in a steam turbine-generator
- Authors
- Ahn, HS; Yoon, ES; Sohn, DG; Kwon, OK; Shin, KS; Nam, CH
- Issue Date
- 1996-02
- Publisher
- BUTTERWORTH-HEINEMANN LTD
- Citation
- TRIBOLOGY INTERNATIONAL, v.29, no.2, pp.161 - 168
- Abstract
- In order to identify the level of contamination of lubricating oil in a turbine-generator at a local power plant, contaminant analysis was conducted. The contaminant analysis was also used to assess the condition of tribe-components such as bearings, gears and bearing deflectors. Oil samples were taken and the debris in the used lubricating oil were analysed off-line to provide information for the construction of an on-line monitoring system. Statistical analysis of debris was also carried out to determine the quantitative trend of oil contamination. The on-line contaminant monitoring system was then developed with the capabilities to provide an early warning of excessive oil contamination and to detect any impending failures of tribe-components. Guidelines necessary for maintenance engineers such as preset warning level and a trip level (automatic shutdown) of contamination were established. In the system, a device utilizing a filter blockage principle was employed to measure the contamination level. The on-line system developed was installed and field tested in a turbine-generator at a local power plant. During the two year period of investigation, the lubricating system and related tribo-components were revealed to be in normal condition.
- ISSN
- 0301-679X
- URI
- https://pubs.kist.re.kr/handle/201004/144553
- DOI
- 10.1016/0301-679X(95)00003-M
- Appears in Collections:
- KIST Article > Others
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.