TRANSIENT-RESPONSE OF NONLINEAR PROTECTIVE DEVICES FOR SUPPRESSION OF LIGHTNING SURGES ON A PAIR-WIRE LINE

Authors
김세윤하헌태
Issue Date
1991-10
Publisher
IEICE-INST ELECTRON INFO COMMUN ENG
Citation
IEICE TRANSACTIONS ON COMMUNICATIONS ELECTRONICS INFORMATION AND SYSTEMS, v.74, pp.3018 - 3023
Abstract
A successive iteration algorithm for estimating the response of a parallel two-wire transmission line terminated by nonlinear protective devices in an external electromagnetic pulse is developed and implemented for numerical simulation. The validity of the presented algorithm is assured by showing that the numerical result for a particular nonlinear impedance characteristics of the protective devices approaches the rigorous solution which is also derived here analytically.