Full metadata record

DC Field Value Language
dc.contributor.authorHAN, DK-
dc.contributor.authorJEONG, SY-
dc.contributor.authorKIM, YH-
dc.contributor.authorMIN, BG-
dc.contributor.authorCHO, HI-
dc.date.accessioned2024-01-21T23:44:54Z-
dc.date.available2024-01-21T23:44:54Z-
dc.date.created2022-01-10-
dc.date.issued1991-05-
dc.identifier.issn0021-9304-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/146802-
dc.description.abstractIn order to investigate the interaction between various sulfonated polyurethanes (PUs) and blood, a commercial PU surface was chemically modified by poly(ethylene oxide) (PEO), dodecanediol(DDO), and propane sultone to give hydrophilic, hydrophobic, and negative sulfonated surfaces, respectively. The blood compatibility of modified PUs was evaluated by an in vitro platelet adhesion test, activated partial thromboplastin time (APTT), and prothrombin time (PT) measurements as well as an ex vivo rabbit A-A shunt method. In the platelet adhesion test, the hydrophilic PEO grafted PUs showed less platelet adhesion than untreated PU and hydrophobic DDO grafted PU. Sulfonated PU-PEO exhibited a lower degree of adhesion and shape change of platelet. The APTT and PT, especially APTT, of the sulfonated PUs were extended, whereas those of PU-PEO and PU-DDO did not show any significant change compared with untreated PU. Meanwhile, in the ex vivo experiment, hydrophilic PEO grafted PUs showed longer occlusion times than untreated PU or hydrophobic DDO grafted PU. In addition, the incorporation of SO3 groups at the end of PU-DDO and PU-PEO, particularly PU-PEO-SO3, exhibited an enormous prolongation in occlusion time, indicating a synergistic effect of the hydrophilic PEO and the negative SO3 groups on thromboresistance. These occlusion times corresponded well to in vitro evaluation results: the less adhesion and shape change of platelet and the longer APTT and PT, the more extended the ex vivo occlusion time.-
dc.languageEnglish-
dc.publisherJOHN WILEY & SONS INC-
dc.subjectHEPARIN-IMMOBILIZED POLYURETHANES-
dc.subjectBLOOD COMPATIBILITY-
dc.subjectSURFACES-
dc.titleNEGATIVE CILIA CONCEPT FOR THROMBORESISTANCE - SYNERGISTIC EFFECT OF PEO AND SULFONATE GROUPS GRAFTED ONTO POLYURETHANES-
dc.typeArticle-
dc.identifier.doi10.1002/jbm.820250502-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJOURNAL OF BIOMEDICAL MATERIALS RESEARCH, v.25, no.5, pp.561 - 575-
dc.citation.titleJOURNAL OF BIOMEDICAL MATERIALS RESEARCH-
dc.citation.volume25-
dc.citation.number5-
dc.citation.startPage561-
dc.citation.endPage575-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosidA1991FG76700001-
dc.identifier.scopusid2-s2.0-0026155445-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryMaterials Science, Biomaterials-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMaterials Science-
dc.type.docTypeArticle-
dc.subject.keywordPlusHEPARIN-IMMOBILIZED POLYURETHANES-
dc.subject.keywordPlusBLOOD COMPATIBILITY-
dc.subject.keywordPlusSURFACES-
dc.subject.keywordAuthorblood compatibility-
dc.subject.keywordAuthorgrafting of sulfonated PEO-
dc.subject.keywordAuthorpolyurethane-
Appears in Collections:
KIST Article > Others
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE