- Magnetic capsule robots (MCRs) have been widely studied in recent years for medical use since they can perform noninvasive procedures and patient-friendly diagnostics. Magnetic actuation, which is one of the most reliable wireless motion control techniques for a magnetic capsule endoscope in the body, has also been extensively studied. However, there are challenges associated with cooperativeness with clinicians and convenience for patients, especially since a large workspace is required with a small actuation system. To achieve unobtrusive actuation of MCRs, we propose a method, which involves the use of a novel mobile electromagnetic actuation (MEMA) system, for enhancing motion control of a magnetically actuated capsule robot. This actuation system comprises a robotic arm, a motorized XY linear stage, and electromagnetic coils, and it can provide a movable workspace on both sides of a patient's bed. A disturbance observer based robust feedback controller was also designed to compensate for the hardware singularity and model uncertainty of a multiple magnetic field model. The MEMA system and controller can help accurately operate an MCR at all locations-on the floor, wall, and ceiling-of the target volume. Translational and rotational motions of an MCR were experimentally achieved, and the maximum angular scanning error of 0.87 degrees could be achieved with the proposed control. Finally, the practicality of the MEMA system for enhanced endoscopic motion could be validated through a hybrid control scheme.
- Keywords
- TRACKING CONTROLLER; Robots; Coils; Magnetic levitation; Soft magnetic materials; Magnetic resonance imaging; Robot kinematics; Electromagnets; Torque; Actuators; Motion control; Electromagnetic actuation; magnetic capsule robot (MCR); magnetic field; robust control
- ISSN
- 1083-4435
- URI
- https://pubs.kist.re.kr/handle/201004/152108
- DOI
- 10.1109/TMECH.2024.3521373
- Appears in Collections:
- KIST Article > Others
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.