Effects of a hydrophilic surface in anodic bonding
- Authors
- Lee, DJ; Ju, BK; Jang, J; Lee, KB; Oh, MH
- Issue Date
- 1999-12
- Publisher
- IOP PUBLISHING LTD
- Citation
- JOURNAL OF MICROMECHANICS AND MICROENGINEERING, v.9, no.4, pp.313 - 318
- Abstract
- This paper presents a study of the anodic bonding technique using a hydrophilic surface. Our method differs from conventional processes in the pre-treatment of the wafer. Hydrophilic surfaces were achieved from dipping in H2O/H2O2/NH4OH solution. The hydrophilic surface has a large number of -OH groups, which can form hydrogen bonds when two wafers are in contact. This induces a higher electrostatic force, because of the decreasing gap between the glass and silicon wafer. We achieved improved properties, such as a wider bonded area and a higher bond strength than those of conventional methods. Also, the fabricated pressure sensors on the 5-inch silicon wafer were bonded to Pyrex #7740 glass of 3 mm thickness. In order to investigate the migration of the sodium ions, the depth profile at the glass surface by secondary-ion mass spectroscopy and the bonding current were compared with that of conventional methods.
- Keywords
- SILICON; SILICON; MEMS
- ISSN
- 0960-1317
- URI
- https://pubs.kist.re.kr/handle/201004/141807
- DOI
- 10.1088/0960-1317/9/4/305
- Appears in Collections:
- KIST Article > Others
- Files in This Item:
There are no files associated with this item.